Digital Multifunction Power Quality Measurement Device - SHM Model

Digital Multifunction Power Quality Measurement Device - SHM Model for Accurate Energy Monitoring

Manufacturer:ELECTROPRIBOR OJSC
Price:Request Quote

Bulk pricing available

FOB, CIF & EXW terms available

Description

The ShchMK120S device is designed for measurement, control and registration of the main parameters of electrical energy up to the 50th harmonic in single-phase two-wire and three-phase three-wire and four-wire electrical networks and AC power supply systems with a nominal frequency of 50 Hz; measurement, registration and metering of active and reactive electrical energy for specified time intervals in three-phase AC networks (including technical and commercial metering of active and reactive electricity) in accordance with the requirements of the Russian Federation State Register of Measuring Instruments No. 617-16-16. ShchMK120S is included in the State Register of measuring instruments of the Russian Federation No. 60431-15. Interverification interval - 10 years.

Specifications

Average MTBF
250000 ?
Overall dimensions, mm
120?120?93 (without protective cover), 120?120?103 (with cover)
Weight, kg, not more
0,7
LED indication
3 blocks of seven-segment indicators (4 indicators per block); single LED indicators for displaying units of measurement, distinctive indices and signs of displayed parameters; sign height: 20 mm; seven-segment indicators for displaying the current state o
Input signal
1 A, 5 A, I/1 A, I/5 A, 100 V, 400 V, U/100 V; voltage rating: 57.73/230 V - phase, 100/400 V - interphase; input measurement frequency: 42.5 to 57.5 Hz
Measurement time
0.2 sec (current and voltage), 1 sec (frequency)
Power quality parameters
Voltage short-circuit; positive voltage deviation; negative voltage deviation; frequency; frequency deviation; short-term flicker dose; long-term flicker dose; voltage n-harmonic coefficient up to 50th order; summaries
Commercial electricity metering
Active energy received/released/summed at 8 tariffs; reactive energy received/released/summed/ by r-th quadrant (r = 1, 2, 3, 4) at 8 tariffs
Compliance of PCE measurements with the established Russian standards
GOST 30804.4.30-2013 ; GOST 32144-2013 ; GOST 30804.4.7-2013 (Class I) ; GOST R 51317.4.15-2012 ; GOST R 8.655-2009 ; GOST R 8.689-2009
Compliance with requirements for active and reactive energy meters
GOST 31819.22-2012 (Class 0,2S); GOST 31819.23-2012 (Class 1); GOST 31818.11-2012; GOST IEC 61107-2011
Galvanic isolation on the power supply circuit (main or backup) and on the input circuits
Got it
RS485 communication interface
Quantity: 2; protocols: Modbus RTU, IEC 60870-5-101 Interface exchange rate: 200, 300, 600, 1200, 1200, 2400, 4800, 4800, 9600, 19200, 38400, 57600, 115200 bits/sec.
Ethernet communication interface
Quantity: 2; Ethernet 10/100BASE-TX (RJ45 connector) or Ethernet 100BASE-FX (ST connector) Protocols: IEC 60870-5-104, Modbus TCP, IEC 61850-8-1 (MMS), IEC 61850-9-2 (SV) - optional
Remote human-machine interface
HTTP (embedded web interface) with access by device IP address
Integration into the system of control of power quality indicators
HTTP (integration into the software package for visualization and control of power quality indicators supplied with the device)
Integration into external systems: telemetering, telemechanics, automated process control systems, SM&KE, ASCUE
IEC 60870-5-104, IEC 61850-8-1 (MMS), Modbus TCP, IEC 60870-5-101, Modbus RTU
Time synchronization
NTP (RFC 5905)/PTP (IEEE `1588); clock error is not more than ±1 sec. per day; in the absence of external power supply, the clock can operate for at least 15 days.
Event logs
System event log - up to 1000 events with automatic overwriting of earlier events when the maximum is reached; power quality event log - up to 100 thousand events with automatic overwriting of earlier events when the maximum is reached.
Storage of measurement results
In the internal non-volatile memory of measured PCE values; cyclic buffer for storing profiles of all values with a storage depth of at least 90 days (2160 hours) with automatic overwriting of earlier records after the free space is exhausted.
Electricity test protocol
In accordance with GOST 32144-2013 for any time interval not less than 90 days.
Power supply voltage
Main: 220VU (from 90 to 264 V AC with frequency (50 ± 0.5) Hz or from 130 to 370 V DC); standby ("RESERVE"): 220VU (90 to 264 VAC with a frequency of (50 ± 0.5) Hz or 130 to 370 VDC)
Power consumption from the power supply circuit, not more
10 V?A (full power) when powered by 50 Hz single-phase AC power supply, 10 W when powered by DC power supply
Reprogramming
Via "Configurator" programme (RS485, Ethernet interface), via web-interface
Operating temperature range
-40 to +55 °C (relative humidity 90% at +30 °C)
Degree of protection
IP51
Resistance to mechanical influences
Group 4 according to GOST 22261-94
Industrial noise level
GOST 30805.22-2013 for class A equipment
Inspection interval
10 years
Warranty period of operation
36 mos.
Average service life, at least
30 years

Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.

Save Your Time

Share your requirements for a quick response!

Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer

Delivery & Payment

Shipping Terms

FOB Novorossiysk, RussiaCIF Available to major ports worldwideEXW Manufacturer's facility, Russia

Delivery Time

Sea freight: 30-60 days (depending on destination) Air freight: 14-21 days (for urgent orders)

Payment Methods

Letter of Credit (L/C)Wire Transfer (T/T)Escrow Services

Similar Products You May Be Interested In

Verified Suppliers

All products are sourced directly from authorized Russian manufacturers

Quality Assurance

Products meet international quality standards with proper certification

Global Shipping

Reliable logistics solutions to deliver products to your location

Secure Payments

Multiple secure payment options to facilitate international transactions

Your callback request has been received. We'll contact you shortly.