Digital Panel Meter for Accurate Current and Voltage Measurement, Model Щ20.1

Digital Panel Meter for Current and Voltage Measurement - Model Щ20.1

Manufacturer:ELECTROPRIBOR OJSC
Price:Request Quote

Bulk pricing available

FOB, CIF & EXW terms available

Description

The panelboard digital electrical measuring device Shch20.1 is designed to measure current or voltage in DC circuits for operation as part of the technical means of nuclear power plants, as well as in other industries. The device can be used in a set with primary converters for measurement of non-electrical quantities, if the ranges of the output electrical signal of primary converters correspond to the ranges of the input signal of the devices. The device provides the possibility of selecting the input signal measurement range, changing the reading range and the unit of measurement.

Shch20.1 has the possibility to transfer information to computing devices via RS485 interface (Modbus RTU, original protocol). The device is made in a metal case of shield mounting. The mounting structure is designed for installation in a 50 mm thick shield.

According to the order it is possible to install the device in a shield of other thickness. Safety class of the devices: 2,3,4 according to NP-001-2015.

Specifications

Mounting
In the shield
Overall dimensions, mm
50×25×91
Input signal measurement ranges
0...75 mV (-75...0...75 mV), 0...200 mV (-200...0...200 mV), 0...1 V (-1...0...0...1 V), 0...10 V (-10...0...10 V), 2...10 V, 0...5 mA (-5...0...0...5 mA), 0...20 mA (-20...0...20 mA), 4...20 mA (-12...4...20 mA).
LED indication
Digital switchboard (counting device); digits height: 9 mm; number of indicators: 4; indicator colour: red, yellow, green
Maximum reading range
-1999 to 9999
Alarm
When the upper limit of the input signal measuring range is exceeded by 5 %
Basic error
±0,1%
Galvanic isolation between RS485 interface circuits and input circuits
absent
RS485 communication interface
Quantity: 1; Modbus RTU protocol, original protocol
Power supply voltage
(24 ± 4) VDC
Power consumption from the power supply circuit, not more
1.5 V-A.
Reprogramming
Via "Configurator" program (RS485 interface)
Reprogramming parameters
Measuring range of input signal; reading range of digital DUT; brightness of indicators; parameters of RS485 interface; setting of open circuit and threshold value; calibration of instrument parameters
Operating temperature range
From -10 to +50 °C (relative humidity 98 % at +35 °C)
Degree of protection
IP20
Safety Class
2, 3, 4 according to NP-001-2015
Inspection interval
6 years old
Warranty period of operation
24 mos.
Average service life, at least
15 years
Average MTBF
150000 ?

Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.

Save Your Time

Share your requirements for a quick response!

Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer

Delivery & Payment

Shipping Terms

FOB Novorossiysk, RussiaCIF Available to major ports worldwideEXW Manufacturer's facility, Russia

Delivery Time

Sea freight: 30-60 days (depending on destination) Air freight: 14-21 days (for urgent orders)

Payment Methods

Letter of Credit (L/C)Wire Transfer (T/T)Escrow Services

Similar Products You May Be Interested In

Verified Suppliers

All products are sourced directly from authorized Russian manufacturers

Quality Assurance

Products meet international quality standards with proper certification

Global Shipping

Reliable logistics solutions to deliver products to your location

Secure Payments

Multiple secure payment options to facilitate international transactions

Your callback request has been received. We'll contact you shortly.