"Static, unidirectional three-phase multitariff universal transformer or direct inclusion meter, with built-in microcontroller and with a variety of interfaces counting mechanism to exchange information with external devices. The meter of direct inclusion is designed for accounting of active and reactive electric energy in four-wire AC networks with nominal voltage of 3x230/400V. The basic (maximum) current is 5(100) A.
The meter, switched on through a current transformer, is designed for accounting of active and reactive electrical energy in four-wire AC networks with nominal voltage of 3x230/400V. Rated (maximum) current is 5(10)A. The meter, included through current and voltage transformers, is designed for metering of active and reactive electrical energy in four-wire AC networks with nominal voltage of 3x57.7/100V.
Rated (maximum) current is 5(10)A. The meter is produced in the case: <ul> <li>- 9mTN35 - mounting on the rail TN35 according to GOST R IEC 60715 (DIN-rail), width 157 mm (9 modules of 17.5 mm), IP51.</li> </ul>For each modification of the counters there is a release of versions containing the following additional devices or functions: <ul> <li>- additional communication interface (RS-485, RF868, PLC, PLC.G3/RF868, ZigBee);</li> <li>programmable load switching on/off control output.</li> </ul>Display of consumed electrical energy is carried out on the liquid crystal display (hereinafter - LCD) of the meter. The meter displays readings directly in kilowatt-hours (kWh) when measuring active energy and in kilovar-hours (kvar-h) when measuring reactive energy.
reactive energy measurement. The amount of stored electricity is displayed as eight digits, with the three or two lower digits separated by a comma, representing thousandths or hundredths of kWh (kvarh) for transformer or direct current meters, respectively. The LCD displays:
- - values of accumulated cumulative total of active and reactive energy
- - total (for all tariffs) value of accumulated cumulative total active and reactive energy
- - current active, reactive and total power for each phase and
- - voltage and current for each phase (reference value);
- mains frequency (reference value);
- power factor per phase and total value (reference value); power factor per phase and total value (reference value); power factor per phase and total value (reference value).
- - phase shift between current and voltage in each phase (reference value); phase shift between current and voltage in each phase (reference value); phase shift between current and voltage in each phase (reference value).
- - phase shift between phase voltages (reference value);
- absence of phase voltage (flashing symbol for phase A, B or C);
- open key symbol (if the terminal block cover is not fitted);
- backup battery voltage (reference value);
- current time and date;
- network address of the meter;
- software version;
- software numeric identifier;
- date and time of the last access to the optional interface.
- - values of metered active and reactive energy accumulated cumulatively from the moment of manufacture
- - values of metered active and reactive energy by tariffs for each month of the year;
- values of metered active and reactive energy per day according to tariffs for the last 123 days;
- values of metered active and reactive energy, as well as maximum active and reactive power
- - instantaneous values of active, reactive and full load power
- - instantaneous values of effective voltage and current for each phase
- - clock calibration factor;
- voltage of the built-in battery of the backup power supply (reference value); voltage of the built-in battery of the backup power supply (reference value)
- - annual tariff schedule and exceptional (public) days;
- modification and serial (factory) number of the meter;
- serial number of the printing unit;
- software version number (identification number);
- digital identifier (checksum) of the software;
- time and date of opening of terminal covers;
- power on/off time;
- time and date of the start and end of magnetic field exposure."
Specifications
Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.
Share your requirements for a quick response!
Delivery & Payment
Shipping Terms
Delivery Time
Payment Methods
Similar Products You May Be Interested In

Static Multirate Energy Meter Milur 107 TSKYa.411152.006-03.XXX
View Details
EMIS-ELECTRA 976 Electric Energy Meter - Type "C
View Details
Static Single-Phase Energy Meter FOСHOS 1M 230V 5(80)A IQOLM(1)-C
View Details
Multifunctional Single-Phase Electric Energy Meter "MIRTEX-12-RU" W9 Case
View Details
Smart Single-Phase Energy Meter NARTIS-I100-W112-2
View Details
Multifunctional Single-Phase Energy Meter "MIRTEX-12-RU" W6b
View Details
Multifunctional Three-Phase Energy Meter MIRTек-32-РУ-SP37-1
View Details
Static Three-Phase Electric Energy Meter Milur 307S.52-PRRZ-2-D
View Details
Single-Phase Energy Meter SM409 for Active and Reactive Energy Measurement
View Details
Multifunctional Electric Energy Meter PSC-4TM.05MNT
View Details
Multifunctional Electric Energy Meter SEB-1TM.04T
View Details
Electronic DC Energy Meter SKVT-F-Marsen
View DetailsVerified Suppliers
All products are sourced directly from authorized Russian manufacturers
Quality Assurance
Products meet international quality standards with proper certification
Global Shipping
Reliable logistics solutions to deliver products to your location
Secure Payments
Multiple secure payment options to facilitate international transactions