DDDR BiV "Apollo CRT" Cardiac Pacemaker for Heart Failure Treatment

Implantable DDDR BiV "Apollo CRT" Cardiac Pacemaker for Heart Rhythm Disorders

Manufacturer: CARDIOELECTRONICS LLC
Price: Request Quote

Bulk pricing available

FOB, CIF & EXW terms available

Description

Designed for resynchronisation therapy in patients with chronic heart failure, as well as for the treatment of other heart rhythm disorders. The field of application of the stimulator is surgical and interventional arrhythmology and cardiology. The stimulator consists of an electronics unit, a sensor (accelerometer), a 2.5Ah lithium-fluorocarbon power supply, a titanium alloy housing, and a compound head.

Classification:

  • - climatic execution according to GOST R 50444, GOST 15150 - U category 6;
  • depending on the perceived mechanical effects according to GOST R 50444 - wearable product of group 3; depending on the potential risk of use according to GOST 31508 and in accordance with the order of the Ministry of Health of the Russian Federation? 4n from 06.06.2012 - class 3;
  • safety class of "Apollo CRT" software version 1.00 dated 17.11.2017 in accordance with GOST R IEC 62304 - class C
.

Specifications

Weight
40 year
Dimensions
51x61x10 mm mm
Number of chambers
three-chambered (biventricular)
Amplitude of stimulating pulses of A-, LV- and RV-channel, set during programming, must correspond to one of the following
(0,60±0,5); (1,00±0,50); (1,35±0,5); (1,75±0,5); (2,10±0,7); (2,50±0,7); (2,90±0,7); (3.25±0,7); (3,65±0,9); (4,00±0,9); (4,40±0,9); (4,80±0,9); (5,15±1,2); (5,55±1,2); (5,90±1,2); (6,30±1,2); (7,5±1,8); (9,00±1,8) ?
RV channel sensitivity threshold to R-wave (in DDD mode)
1.0(+0.7;-0.6); 2.0(+0.8;-0.6); 3.0(+0.9;-0.6); 4.0(+0.1;-0.8); 5.0(+1.1;-0.8); 6.0(+1.2;-0.8); 7.0(+1.3;-0.8); 8.0(+1.5;-1.0) mV
Input - output operation modes
monopolar, bipolar
Stimulation modes
DDD(R), DDI(R), DVI(R), DOO(R), VDD(R), AOO(R), AAI(R), AAT(R), VOO(R), VVI(R), VVT(R)
Service life from the moment of implantation
3 year
Stimulation mode switching frequency
90 - 180 in steps of 5 imp/min, manually with the programmer. Mode switching when atrial tachycardia or fibrillation is detected, fast and slow response.
The base frequency of stimulus pulses (stimuli) set during programming shall correspond to one of the following
(30±2); (35±2); (40±2);....(150±2); (155±2); (160±2) imp/minute
Save Your Time

Share your requirements for a quick response!

Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer

Delivery & Payment

Shipping Terms

FOB Novorossiysk, Russia CIF Available to major ports worldwide EXW Manufacturer's facility, Russia

Delivery Time

Sea freight: 30-60 days (depending on destination) Air freight: 14-21 days (for urgent orders)

Payment Methods

Letter of Credit (L/C) Wire Transfer (T/T) Escrow Services

Similar Products You May Be Interested In

Verified Suppliers

All products are sourced directly from authorized Russian manufacturers

Quality Assurance

Products meet international quality standards with proper certification

Global Shipping

Reliable logistics solutions to deliver products to your location

Secure Payments

Multiple secure payment options to facilitate international transactions

Your callback request has been received. We'll contact you shortly.